No item(s) available in cart.

PAUT & TOFD Test Practical Exam Flaw Specimens Metric Version

PAUT And TOFD Pipe to Pipe Weld Joint Flawed Specimen 250mm Dia (Metric Version) Carbon Steel

PAUT And TOFD Pipe to Pipe Weld Joint Flawed Specimen 250mm Dia (Metric Version) Carbon Steel PAUT And TOFD Pipe to Pipe Weld Joint Flawed Specimen Ø250mm Dia Phased Array Ultrasonic Testing (PAUT)-Weld Joint Flawed Specimen Ø250mm Dia- Time-of-flight diffraction ultrasonics Geometry: Pipe to Pipe Butt Weld Joint with Pipe Ø250mm Dia. And 200mm Wide on Either Side of The Weld thickness range >20mm to 30mm (Carbon Steel) Material: Carbon Steel Flaws: 3 or 4 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets. Customized Calibration Test Block and Flaw Specimen also available.

PAUT and TOFD Pipe to Pipe Weld Joint Flawed Specimen Ø400mm Dia Metric Version Carbon Steel

PAUT and TOFD Pipe to Pipe Weld Joint Flawed Specimen Ø400mm Dia Carbon Steel PAUT and TOFD Pipe to Pipe Weld Joint Flawed Specimen Ø400mm Dia Time-of-flight diffraction ultrasonic (TOFD)-Weld Joint Flawed Specimen Ø400mm Dia- Phased Array Ultrasonic Testing (PAUT) Geometry: PAUT And TOFD Pipe Butt Weld Joint Ø400mm Dia Flawed Specimens Pipe to Pipe Butt Weld Joint with Pipe Ø400mm Dia And 250mm Wide on Either Side of The Weld thickness range >25mm to 50mm (Carbon Steel) Material: Carbon Steel Flaws: 3 or 4 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets. Customized Calibration Test Block and Flaw Specimen also available.

PAUT And TOFD Plate TO Plate Weld Flawed Specimen Double V 30mm (Metric Version) Carbon Steel

PAUT And TOFD Plate TO Plate Weld Flawed Specimen Double V 30mm (Metric Version) Carbon Steel PAUT And TOFD Plate TO Plate Weld Flawed Specimen Double V ASYMMETRICAL 1/3+2/3 THK Time-of-flight diffraction ultrasonic (TOFD)-PLATE Weld Joint Flawed Specimen-Phased Array Ultrasonic Testing (PAUT) Geometry: Plate to Plate Double V Butt Weld 400mm Long and 200mm Wide on Either Side of The Weld thickness range > 20mm to 30mm (Carbon Steel) ASYMMETRICAL 1/3+2/3 thickness. Material: Carbon Steel Flaws: 3 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets. Customized Calibration Test Block and Flaw Specimen also available.

PAUT And TOFD Plate TO Plate Weld Flawed Specimen Double V 50mm (Metric Version) Carbon Steel

PAUT And TOFD Plate TO Plate Weld Flawed Specimen Double V 50mm (Metric Version) Carbon Steel PAUT And TOFD Plate TO Plate Weld Flawed Specimen Double V ASYMMETRICAL 1/3+2/3 THK Time-of-flight diffraction ultrasonic (TOFD)-PLATE Weld Joint Flawed Specimen-Phased Array Ultrasonic Testing (PAUT) Geometry: Plate to Plate Double V Butt Weld 500mm Long and 250mm Wide on Either Side of The Weld thickness range > 30mm to 50mm (Carbon Steel) ASYMMETRICAL 1/3+2/3 thickness. Material: Carbon Steel Flaws: 3 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets. Customized Calibration Test Block and Flaw Specimen also available.

PAUT And TOFD Plate to Plate Single V Flawed Specimens 30mm (Metric Version) Carbon Steel

PAUT And TOFD Plate to Plate Single V Flawed Specimens 30mm (Metric Version) Carbon Steel PAUT And TOFD Plate to Plate Single V Flawed Specimens ASYMMETRICAL 1/3+2/3 THK Phased Array Ultrasonic Testing (PAUT) - Plate to Plate Single V Flawed Specimens-Time-of-flight diffraction ultrasonic Geometry: Plate to Plate Double V Butt Weld 400mm Long and 200mm Wide on Either Side of The Weld thickness range > 20mm to 30mm Carbon Steel ASYMMETRICAL1/3+2/3 thickness. Material: Carbon Steel. Flaws: 3 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets. Customized Calibration Test Block and Flaw Specimen also available.

PAUT And TOFD Plate to Plate Single V Flawed Specimens 50mm (Metric Version) Carbon Steel

PAUT And TOFD Plate to Plate Single V Flawed Specimens 50mm (Metric Version) Carbon Steel PAUT And TOFD Plate to Plate Single V Flawed Specimens ASYMMETRICAL 1/3+2/3 THK Phased Array Ultrasonic Testing (PAUT) - Plate to Plate Single V Flawed Specimens-Time-of-flight diffraction ultrasonic Geometry: Plate to Plate Double V Butt Weld 500mm Long and 250mm Wide on Either Side of The Weld thickness range > 30mm to 50mm Carbon Steel ASYMMETRICAL1/3+2/3 thickness. Material: Carbon Steel. Flaws: 3 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets. Customized Calibration Test Block and Flaw Specimen also available.

© 2024 NDE FLAW TECH. All Right Reserved.