Eddy Current Tubular Node Weld Flaw Specimen-ET
Eddy Current Tubular Node Weld Flaw Specimen-ET ET Weld Specimen Specially made for Surface Eddy Current Testing with embedded flaws & amp; coated with primer, epoxy paint & amp; Teflon, TKY Joint Tubular Nodes. Flaws: 3 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.
Eddy Current Tee Joint Weld Flaw Specimen-ECT
Eddy Current Tee Joint Weld Flaw Specimen-ECT ET Weld Specimen Specially made for Surface Eddy Current Testing with embedded flaws & coated with primer, epoxy paint & Teflon, Tee Joint weld Flaws: 3 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.
Eddy Current Pipe Weld Flaw Specimen-ET
Eddy Current Pipe Weld Flaw Specimen-ET ET Weld Specimen Pipe to Pipe ET Weld Specimen Specially made for Surface Eddy Current Testing with embedded flaws & coated with primer, epoxy paint & Teflon, Flaws: 3 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.
Eddy Current Weld Flaw Specimen Plate-ECT
Eddy Current Weld Flaw Specimen Plate-ECT ET Weld Specimen Specially made for Surface Eddy Current Testing with embedded flaws & coated with primer, epoxy paint & Teflon, Plate to Plate weld Flaws: 3 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.
Eddy Current Testing Weld Flaw Specimen Plate-ET
Eddy Current Testing Weld Flaw Specimen Plate-ET ET Weld Specimen Specially made for Surface Eddy Current Testing with embedded flaws & coated with primer, epoxy paint & Teflon, Plate to Plate weld Flaws: 3 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.
Eddy Current ET Weld Flaw Specimens Plate-ECT
Eddy Current ET Weld Flaw Specimens Plate-ECT ET Weld Specimen Specially made for Surface Eddy Current Testing with embedded flaws & coated with primer, epoxy paint & Teflon, Plate to Plate weld Geometry: 10” (L) x 6” (W) x 0.24” to 0.3” (T). Flaws: 3 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.
Eddy Current ECT Cruciform Weld Flaw Specimen
Eddy Current ECT Cruciform Weld Flaw Specimen Eddy Current ECT Cruciform Weld flaw Specimen-ET ECT Weld Specimen Specially made for Surface Eddy Current Testing with embedded flaws & amp; coated with primer, epoxy paint & amp; Teflon, Cruciform Type Joint. Geometry: 12” (L) X 8” (W) X 4” (H) X 0.6” (T). Flaws: 3 to 4 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.
Eddy Current Semi Cruciform Weld Flaw Specimen-ECT
Eddy Current Semi Cruciform Weld Flaw Specimen-ECT Eddy Current Semi Cruciform Weld Flaw Specimen-ECT-ET ET Weld Flaw Specimen Semi Cruciform ET Weld Specimen Specially made for Surface Eddy Current Testing with embedded flaws & coated with primer, epoxy paint & Teflon, Semi Cruciform Type Joint Geometry: 12” (L) X 8” (W) X 4” (H) X 0.6” (T). Flaws: 3 to 4 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.