No item(s) available in cart.

IIW-Type 2 Calibration Test Block (Metric Version)

Metric Version

IIW-Type 2 Calibration Test Block (Metric Version) Special Alloy

IIW-Type 2 Calibration Test Block (Metric Version) Special Alloy IIW type blocks are used to calibrate instruments for both angle beam and normal incident inspections. Some of their uses include setting metal-distance and sensitivity settings, determining the sound exit point and refracted angle of angle beam transducers, and evaluating depth resolution of normal beam inspection setups. Instructions on using the IIW type blocks can be found in the annex of American Society for Testing and Materials Standard E164, Standard Practice for Ultrasonic Contact Examination of Weldments. A modified version of the original IIW-Type 1 design in a metric version. Includes a 50mm radius x 5.0mm deep cut-out superposed on the 100mm radius for distance calibration. Also includes 1.0mm, 2.0mm and 3.0mm through holes for sensitivity testing or surface wave inspection, and distance calibration marks to the 50mm hole. NDE FLAW design based on International Institute of Welding, ASTM E164 and U.S. Air Force NDI Manual T.O. 33B-1-1 specifications. Dimensions: 300mm x 100mm x 25mm Material: Special Alloy.

IIW-Type 2 Calibration Test Block (Metric Version) 4340 Steel

IIW-Type 2 Calibration Test Block (Metric Version) 4340 Steel IIW type blocks are used to calibrate instruments for both angle beam and normal incident inspections. Some of their uses include setting metal-distance and sensitivity settings, determining the sound exit point and refracted angle of angle beam transducers, and evaluating depth resolution of normal beam inspection setups. Instructions on using the IIW type blocks can be found in the annex of American Society for Testing and Materials Standard E164, Standard Practice for Ultrasonic Contact Examination of Weldments. A modified version of the original IIW-Type 1 design in a metric version. Includes a 50mm radius x 5.0mm deep cut-out superposed on the 100mm radius for distance calibration. Also includes 1.0mm, 2.0mm and 3.0mm through holes for sensitivity testing or surface wave inspection, and distance calibration marks to the 50mm hole. NDE FLAW design based on International Institute of Welding, ASTM E164 and U.S. Air Force NDI Manual T.O. 33B-1-1 specifications. Dimensions: 300mm x 100mm x 25mm Material: 4340 Steel.

IIW-Type 2 Calibration Test Block (Metric Version) 1018 Steel

IIW-Type 2 Calibration Test Block (Metric Version) 1018 Steel IIW type blocks are used to calibrate instruments for both angle beam and normal incident inspections. Some of their uses include setting metal-distance and sensitivity settings, determining the sound exit point and refracted angle of angle beam transducers, and evaluating depth resolution of normal beam inspection setups. Instructions on using the IIW type blocks can be found in the annex of American Society for Testing and Materials Standard E164, Standard Practice for Ultrasonic Contact Examination of Weldments. A modified version of the original IIW-Type 1 design in a metric version. Includes a 50mm radius x 5.0mm deep cut-out superposed on the 100mm radius for distance calibration. Also includes 1.0mm, 2.0mm and 3.0mm through holes for sensitivity testing or surface wave inspection, and distance calibration marks to the 50mm hole. NDE FLAW design based on International Institute of Welding, ASTM E164 and U.S. Air Force NDI Manual T.O. 33B-1-1 specifications. Dimensions: 300mm x 100mm x 25mm Material: 1018 Steel

IIW-Type 2 Calibration Test Block (Metric Version) STAINLESS STEEL 304

IIW-Type 2 Calibration Test Block (Metric Version) STAINLESS STEEL 304 IIW type blocks are used to calibrate instruments for both angle beam and normal incident inspections. Some of their uses include setting metal-distance and sensitivity settings, determining the sound exit point and refracted angle of angle beam transducers, and evaluating depth resolution of normal beam inspection setups. Instructions on using the IIW type blocks can be found in the annex of American Society for Testing and Materials Standard E164, Standard Practice for Ultrasonic Contact Examination of Weldments. A modified version of the original IIW-Type 1 design in a metric version. Includes a 50mm radius x 5.0mm deep cut-out superposed on the 100mm radius for distance calibration. Also includes 1.0mm, 2.0mm and 3.0mm through holes for sensitivity testing or surface wave inspection, and distance calibration marks to the 50mm hole. NDE FLAW design based on International Institute of Welding, ASTM E164 and U.S. Air Force NDI Manual T.O. 33B-1-1 specifications. Dimensions: 300mm x 100mm x 25mm Material: STAINLESS STEEL 304.

IIW-Type 2 Calibration Test Block (Metric Version) STAINLESS STEEL 316

IIW-Type 2 Calibration Test Block (Metric Version) STAINLESS STEEL 316 IIW type blocks are used to calibrate instruments for both angle beam and normal incident inspections. Some of their uses include setting metal-distance and sensitivity settings, determining the sound exit point and refracted angle of angle beam transducers, and evaluating depth resolution of normal beam inspection setups. Instructions on using the IIW type blocks can be found in the annex of American Society for Testing and Materials Standard E164, Standard Practice for Ultrasonic Contact Examination of Weldments. A modified version of the original IIW-Type 1 design in a metric version. Includes a 50mm radius x 5.0mm deep cut-out superposed on the 100mm radius for distance calibration. Also includes 1.0mm, 2.0mm and 3.0mm through holes for sensitivity testing or surface wave inspection, and distance calibration marks to the 50mm hole. NDE FLAW design based on International Institute of Welding, ASTM E164 and U.S. Air Force NDI Manual T.O. 33B-1-1 specifications. Dimensions: 300mm x 100mm x 25mm Material: STAINLESS STEEL 316.

IIW-Type 2 Calibration Test Block (Metric Version) TITANIUM

IIW-Type 2 Calibration Test Block (Metric Version) TITANIUM IIW type blocks are used to calibrate instruments for both angle beam and normal incident inspections. Some of their uses include setting metal-distance and sensitivity settings, determining the sound exit point and refracted angle of angle beam transducers, and evaluating depth resolution of normal beam inspection setups. Instructions on using the IIW type blocks can be found in the annex of American Society for Testing and Materials Standard E164, Standard Practice for Ultrasonic Contact Examination of Weldments. A modified version of the original IIW-Type 1 design in a metric version. Includes a 50mm radius x 5.0mm deep cut-out superposed on the 100mm radius for distance calibration. Also includes 1.0mm, 2.0mm and 3.0mm through holes for sensitivity testing or surface wave inspection, and distance calibration marks to the 50mm hole. NDE FLAW design based on International Institute of Welding, ASTM E164 and U.S. Air Force NDI Manual T.O. 33B-1-1 specifications. Dimensions: 300mm x 100mm x 25mm Material: TITANIUM.

IIW-Type 2 Calibration Test Block (Metric Version) ALUMINUM 7075-T6

IIW-Type 2 Calibration Test Block (Metric Version) ALUMINUM 7075-T6 IIW type blocks are used to calibrate instruments for both angle beam and normal incident inspections. Some of their uses include setting metal-distance and sensitivity settings, determining the sound exit point and refracted angle of angle beam transducers, and evaluating depth resolution of normal beam inspection setups. Instructions on using the IIW type blocks can be found in the annex of American Society for Testing and Materials Standard E164, Standard Practice for Ultrasonic Contact Examination of Weldments. A modified version of the original IIW-Type 1 design in a metric version. Includes a 50mm radius x 5.0mm deep cut-out superposed on the 100mm radius for distance calibration. Also includes 1.0mm, 2.0mm and 3.0mm through holes for sensitivity testing or surface wave inspection, and distance calibration marks to the 50mm hole. NDE FLAW design based on International Institute of Welding, ASTM E164 and U.S. Air Force NDI Manual T.O. 33B-1-1 specifications. Dimensions: 300mm x 100mm x 25mm Material: ALUMINUM 7075-T6.

IIW-Type 2 Calibration Test Block (Metric Version) INCONEL 625

IIW-Type 2 Calibration Test Block (Metric Version) INCONEL 625 IIW type blocks are used to calibrate instruments for both angle beam and normal incident inspections. Some of their uses include setting metal-distance and sensitivity settings, determining the sound exit point and refracted angle of angle beam transducers, and evaluating depth resolution of normal beam inspection setups. Instructions on using the IIW type blocks can be found in the annex of American Society for Testing and Materials Standard E164, Standard Practice for Ultrasonic Contact Examination of Weldments. A modified version of the original IIW-Type 1 design in a metric version. Includes a 50mm radius x 5.0mm deep cut-out superposed on the 100mm radius for distance calibration. Also includes 1.0mm, 2.0mm and 3.0mm through holes for sensitivity testing or surface wave inspection, and distance calibration marks to the 50mm hole. NDE FLAW design based on International Institute of Welding, ASTM E164 and U.S. Air Force NDI Manual T.O. 33B-1-1 specifications. Dimensions: 300mm x 100mm x 25mm Material: INCONEL 625.

IIW-Type 2 Calibration Test Block (Metric Version) MONAL 800

IIW-Type 2 Calibration Test Block (Metric Version) MONAL 800 IIW type blocks are used to calibrate instruments for both angle beam and normal incident inspections. Some of their uses include setting metal-distance and sensitivity settings, determining the sound exit point and refracted angle of angle beam transducers, and evaluating depth resolution of normal beam inspection setups. Instructions on using the IIW type blocks can be found in the annex of American Society for Testing and Materials Standard E164, Standard Practice for Ultrasonic Contact Examination of Weldments. A modified version of the original IIW-Type 1 design in a metric version. Includes a 50mm radius x 5.0mm deep cut-out superposed on the 100mm radius for distance calibration. Also includes 1.0mm, 2.0mm and 3.0mm through holes for sensitivity testing or surface wave inspection, and distance calibration marks to the 50mm hole. NDE FLAW design based on International Institute of Welding, ASTM E164 and U.S. Air Force NDI Manual T.O. 33B-1-1 specifications. Dimensions: 300mm x 100mm x 25mm Material: MONAL 800.

© 2024 NDE FLAW TECH. All Right Reserved.Designed & Developed by Innov Touch Technologies Pvt Ltd.