PAUT-Phased Array Standard Calibration Blocks (Metric Version) 1018 Steel
Price: $993.00
Part Number : NDE FLAW TECH-PAUT CALIBRATION-222
Availability : In Stock
Description
PAUT-Phased Array Standard Calibration Blocks (Metric Version) 1018 Steel
Phased Array Calibration Standard Blocks are used for angle beam verification, probe angle exit points, calibration for wedge delay, sensitivity and DAC/TCG for thicknesses up to 50mm. The reference block shall be used which allows a minimum of a 3 point TCG establishment throughout the range specified in the scan plan for all configured angles . The block shall be made of sufficient thickness and length to allow calibration of reflectors throughout the entire examination volume to be tested. Each reference block shall have at least three side drilled holes at a range of depths to cover the entire material range to be tested. Each hole shall be detected by the PAUT system as configured per the scan plan and sensitivities shall be adjusted as necessary to provide sensitivity equal to or greater than SSL.
Geometry: The three radii (12.5mm, 25mm and 50mm) allow for exit point verification, velocity and sound path calculations. This metric block contains five holes at 1.2mm diameter drilled through the 25mm width, located at 2.5mm, 5.0mm, 10.0mm, 15.0mm, 20.0mm, 30.0mm, 35.0mm, 45.0mm, 40.0mm and 47.5mm from the respective scanning surface.
Dimensions: 450mm x 50mm x 25mm
Material: 1018 Steel