No item(s) available in cart.

ISO 9712 TKY TRAINING KIT

ISO 9712 TKY TRAINING KIT (Inch Version)

ISO 9712 TKY TRAINING KIT (Inch Version) ISO 9712 TKY training kit, contains 8 specimens, Include 4 T-plates, 2 Node joints and 2 Nozzle joints. Flaws include sub-surface flaws. Specimen Details: • (1) Single V 90° T-Plate Connection- 0.8″ (T) x 12″ (Weld Length) x 8″ (Base) x 8″ (Branch) • (1) Double V 90° T-Plate Connection- 1.0″ (T) x 12″ (Weld Length) x 8″ (Base) x 8″ (Branch) • (1) 45° “Y” Connection- 0.75″ (T) x 12″ (Weld Length) x 4″ (Base) x 8″ (Branch) • (1) 60° “Y” Connection.- 0.75″ (T) x 12″ (Weld Length) x 4″ (Base) x 8″ (Branch) • (1) 30° Node Pipe to Pipe – Branch pipe Ø4” sch 120 (wall thickness – 0.438”) x 6” (L) Base pipe Ø24” sch 60 (180°) x wall thickness 0.968” • (1) 60° Node Pipe to Pipe – Branch pipe Ø4” sch 120 (wall thickness – 0.438”) x 6” (L) Base pipe Ø24” sch 60 (180°) x wall thickness 0.968” • (1) Nozzle Set ON joint – Branch pipe Ø4” sch 120 (wall thickness – 0.438”) x 6” (L) Base pipe Ø24” sch 60 (180°) x wall thickness 0.968” • (1) Nozzle Set Through joint – Branch pipe Ø4” sch 120 (wall thickness – 0.438”) x 6” (L) Base pipe Ø24” sch 60 (180°) x wall thickness 0.968”

ISO 9712 TKY TRAINING KIT (Metric Version)

ISO 9712 TKY TRAINING KIT (Metric Version) ISO 9712 TKY training kit, contains 8 specimens, Include 4 T-plates, 2 Node joints and 2 Nozzle joints. Flaws include sub-surface flaws. Specimen Details: • (1) Single V 90° T-Plate Connection- 20mm (T) x 300mm (Weld Length) x 200mm (Base) x 200mm (Branch) • (1) Double V 90° T-Plate Connection- 25mm (T) x 300mm (Weld Length) x 200mm (Base) x 200mm (Branch) • (1) 45° “Y” Connection- 20mm (T) x 300mm (Weld Length) x 100mm (Base) x 200mm (Branch) • (1) 60° “Y” Connection.- 20mm (T) x 300mm (Weld Length) x 100mm (Base) x 200mm (Branch) • (1) 30° Node Pipe to Pipe – Branch pipe Ø100mm sch 120 (wall thickness – 10mm) x 150mm (L) Base pipe Ø600mm sch 60 (180°) x wall thickness 25mm • (1) 60° Node Pipe to Pipe – Branch pipe Ø100mm sch 120 (wall thickness – 10mm) x 150mm (L) Base pipe Ø600mm sch 60 (180°) x wall thickness 25mm • (1) Nozzle Set ON joint – Branch pipe Ø100mm sch 120 (wall thickness – 10mm) x 150mm (L) Base pipe Ø600mm sch 60 (180°) x wall thickness 25mm • (1) Nozzle Set Through joint – Branch pipe Ø100mm sch 120 (wall thickness – 10mm) x 150mm (L) Base pipe Ø600mm sch 60 (180°) x wall thickness 25mm

© 2024 NDE FLAW TECH. All Right Reserved.Designed & Developed by Innov Touch Technologies Pvt Ltd.

ISO 9712 TKY TRAINING KIT