Calibration Block No.1 (Inch Version) Special Alloy
Calibration Block No.1 (Inch Version) Special Alloy Calibration Block No.1 are used to calibrate instruments for both angle beam and normal incident inspections. Some of their uses include setting metal-distance and sensitivity settings, determining the sound exit point and refracted angle of angle beam transducers, and evaluating depth resolution of normal beam inspection setups. For calibrating ultrasonic flaw detection equipment in both laboratory and on-site conditions. Our version of this block includes a 4" radius, 0.12" and 2" holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 4" range. In accordance with EN 12223 and ISO 2400. This block is not to be confused with the older style "V1/5 (A2)" Block from BS 2704, which is similar but contains a 0.06" through-hole rather than a 0.12" hole. Geometry: 4" radius, 0.12" and 2" holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 4" range. Dimensions: 12"(L) x 4"(W) x 1"(T). Material: Special Alloy
Calibration Block No.1 (Inch Version) 1018 Steel
Calibration Block No.1 (Inch Version) 1018 Steel Calibration Block No.1 are used to calibrate instruments for both angle beam and normal incident inspections. Some of their uses include setting metal-distance and sensitivity settings, determining the sound exit point and refracted angle of angle beam transducers, and evaluating depth resolution of normal beam inspection setups. For calibrating ultrasonic flaw detection equipment in both laboratory and on-site conditions. Our version of this block includes a 4" radius, 0.12" and 2" holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 4" range. In accordance with EN 12223 and ISO 2400. This block is not to be confused with the older style "V1/5 (A2)" Block from BS 2704, which is similar but contains a 0.06" through-hole rather than a 0.12" hole. Geometry: 4" radius, 0.12" and 2" holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 4" range. Dimensions: 12"(L) x 4"(W) x 1"(T). Material: 1018 Steel
Calibration Block No.1 (Inch Version) STAINLESS STEEL 304
Calibration Block No.1 (Inch Version) STAINLESS STEEL 304 Calibration Block No.1 are used to calibrate instruments for both angle beam and normal incident inspections. Some of their uses include setting metal-distance and sensitivity settings, determining the sound exit point and refracted angle of angle beam transducers, and evaluating depth resolution of normal beam inspection setups. For calibrating ultrasonic flaw detection equipment in both laboratory and on-site conditions. Our version of this block includes a 4" radius, 0.12" and 2" holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 4" range. In accordance with EN 12223 and ISO 2400. This block is not to be confused with the older style "V1/5 (A2)" Block from BS 2704, which is similar but contains a 0.06" through-hole rather than a 0.12" hole. Geometry: 4" radius, 0.12" and 2" holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 4" range. Dimensions: 12"(L) x 4"(W) x 1"(T). Material: STAINLESS STEEL 304.
Calibration Block No.1 (Inch Version) STAINLESS STEEL 316
Calibration Block No.1 (Inch Version) STAINLESS STEEL 316 Calibration Block No.1 are used to calibrate instruments for both angle beam and normal incident inspections. Some of their uses include setting metal-distance and sensitivity settings, determining the sound exit point and refracted angle of angle beam transducers, and evaluating depth resolution of normal beam inspection setups. For calibrating ultrasonic flaw detection equipment in both laboratory and on-site conditions. Our version of this block includes a 4" radius, 0.12" and 2" holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 4" range. In accordance with EN 12223 and ISO 2400. This block is not to be confused with the older style "V1/5 (A2)" Block from BS 2704, which is similar but contains a 0.06" through-hole rather than a 0.12" hole. Geometry: 4" radius, 0.12" and 2" holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 4" range. Dimensions: 12"(L) x 4"(W) x 1"(T). Material: STAINLESS STEEL 316.
Calibration Block No.1 (Inch Version) TITANIUM
Calibration Block No.1 (Inch Version) TITANIUM Calibration Block No.1 are used to calibrate instruments for both angle beam and normal incident inspections. Some of their uses include setting metal-distance and sensitivity settings, determining the sound exit point and refracted angle of angle beam transducers, and evaluating depth resolution of normal beam inspection setups. For calibrating ultrasonic flaw detection equipment in both laboratory and on-site conditions. Our version of this block includes a 4" radius, 0.12" and 2" holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 4" range. In accordance with EN 12223 and ISO 2400. This block is not to be confused with the older style "V1/5 (A2)" Block from BS 2704, which is similar but contains a 0.06" through-hole rather than a 0.12" hole. Geometry: 4" radius, 0.12" and 2" holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 4" range. Dimensions: 12"(L) x 4"(W) x 1"(T). Material: TITANIUM.
Calibration Block No.1 (Inch Version) ALUMINUM 7075-T6
Calibration Block No.1 (Inch Version) ALUMINUM 7075-T6 Calibration Block No.1 are used to calibrate instruments for both angle beam and normal incident inspections. Some of their uses include setting metal-distance and sensitivity settings, determining the sound exit point and refracted angle of angle beam transducers, and evaluating depth resolution of normal beam inspection setups. For calibrating ultrasonic flaw detection equipment in both laboratory and on-site conditions. Our version of this block includes a 4" radius, 0.12" and 2" holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 4" range. In accordance with EN 12223 and ISO 2400. This block is not to be confused with the older style "V1/5 (A2)" Block from BS 2704, which is similar but contains a 0.06" through-hole rather than a 0.12" hole. Geometry: 4" radius, 0.12" and 2" holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 4" range. Dimensions: 12"(L) x 4"(W) x 1"(T). Material: ALUMINUM 7075-T6
Calibration Block No.1 (Inch Version) INCONEL 625
Calibration Block No.1 (Inch Version) INCONEL 625 Calibration Block No.1 are used to calibrate instruments for both angle beam and normal incident inspections. Some of their uses include setting metal-distance and sensitivity settings, determining the sound exit point and refracted angle of angle beam transducers, and evaluating depth resolution of normal beam inspection setups. For calibrating ultrasonic flaw detection equipment in both laboratory and on-site conditions. Our version of this block includes a 4" radius, 0.12" and 2" holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 4" range. In accordance with EN 12223 and ISO 2400. This block is not to be confused with the older style "V1/5 (A2)" Block from BS 2704, which is similar but contains a 0.06" through-hole rather than a 0.12" hole. Geometry: 4" radius, 0.12" and 2" holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 4" range. Dimensions: 12"(L) x 4"(W) x 1"(T). Material: INCONEL 625.
Calibration Block No.1 (Inch Version) MONAL 800
Calibration Block No.1 (Inch Version) MONAL 800 Calibration Block No.1 are used to calibrate instruments for both angle beam and normal incident inspections. Some of their uses include setting metal-distance and sensitivity settings, determining the sound exit point and refracted angle of angle beam transducers, and evaluating depth resolution of normal beam inspection setups. For calibrating ultrasonic flaw detection equipment in both laboratory and on-site conditions. Our version of this block includes a 4" radius, 0.12" and 2" holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 4" range. In accordance with EN 12223 and ISO 2400. This block is not to be confused with the older style "V1/5 (A2)" Block from BS 2704, which is similar but contains a 0.06" through-hole rather than a 0.12" hole. Geometry: 4" radius, 0.12" and 2" holes, engraved reference mark scales, and two optional slots at the zero point which provide calibrating signals at intervals of 4" range. Dimensions: 12"(L) x 4"(W) x 1"(T). Material: MONAL 800.