Boiler Tube Damage Kit
Boiler Tube Damage Kit Officially Licensed by EPRI Kit contains 19 Boiler Tubes with various damage indications manufactured by NDE FLAW TECH while incorporating EPRI Technology; representing a complete range of fossil-fired boiler tube failure mechanisms steam and water touched. Material: 18 tubes are SA513 Type 5 Gr1020/1026 c/s and 1 tube is 304/304L s/s. Tube Specifications: (18 tubes) @ 64mm OD x 6mm Wall x ~200mm Long and (1 tube) @ 38mm OD x 6mm Wall x ~200mm Long Flaws / Indications: • Long Term Overheating/Creep • Fire Side Corrosion (Coal) • Toe Crack, Stress Corrosion (Stainless tube) • Soot Blower Erosion • Fatigue Crack (Toe) • Maintenance Damage • Pitting • Rubbing/Fretting • Chemical Cleaning Damage (Thinning & Pitting) • Material Flaw (Forging Lap) • Corrosion Fatigue Crack • Fly Ash Erosion, Hydrogen Damage • Acid Phosphate Corrosion • Caustic Gouging • Supercritical Waterwall Cracking (1.5″ OD tube) • Weld Defects (Lack of Fusion & Porosity) • Graphitization Document Package: Includes C of C, “As Built” Drawings, Ultrasonic Report, Measuring & Test Equipment Certificates and Material Test Reports. Carrying Case: Included (Rolling & Lockable) Kit Weight & Dimensions: ~53KGS, 24” x 16” x 10” EPRI Program 63 Members Receive a Special Discount. Use This Kit to Assist in the Training and Qualifying of NDE Technicians to Accurately Identify Specific Boiler Tube Damage Found in Fossil Plants.